GTI 200W-1KW DC10.5V-28V

GTI 200W-1KW DC10.5V-28V

Easy operation:Directly connected to the solar panels(10.5V to 28V).

 

In order to achieve higher power use requirements, this product can be stacked, such as: 4 grid inverter1000W stacking can achieve 4000W.And the number of the stacking is unlimited. 


Notice:Model GTI 1000W can also be customized as DC input 20V-40V/24V-48V for 36V panels.

Need More Info?Feel free to contact with our customers service manager@powerelek.com ,we will give u the reply within 24 hours! 

System Function                                             

1,directly connected to the solar panels (do not need to connect the battery)

2,AC 0 angle with high precision auto-detection

Synchronous High-frequency Modulation

  Pure Sine Wave Output

3,Automatic Sensing Function Solar Luminosity

  Power Automatically Locked (APL)

  Maximum Power Point Tracking (MPPT)

  Automatically Adapt To Different Load Power Factor

4,Constant Current, Constant Power

5,Current Limit Protection

6,Stack Multiple Machines

7,High-Frequency High Conversion Rate


Parameter Table:

Grid-series models GTI-***

200W

300W

400W

500W

600W

800W

1000W

Recommend use solar panels

320Wp

420Wp

520Wp

620Wp

720Wp

1050Wp

1250Wp

DC Maximum Input Power

300W

400W

500W

600W

700W

900W

1200W

DC maximum voltage

VpvDC30.2VDC

DC voltage range

Vpv 10.5V~28VDC

Maximum output power factor

99%

Maximum input current

15A

20A

25A

30A

40A

45A

65A

AC output power

200W

300W

400W

500W

600W

800W

1000W

AC maximum output power

200W

300W

400W

500W

600W

1000W

Anti-voltage protection

Fuse

AC standard voltage range

90V-140/180~260VAC

AC frequency range

55Hz~63Hz/ 45Hz-53Hz

Output current total

harmonic distortion

THDIAC <5%

Phase

<1%

Islanding protection

VAC;f AC

Output short circuit protection

 Current-limiting

Show

 LED

Installation

Wall hanging

Cooling

Fan

Standby Power

<2W

Night Power

<1W

Ambient temperature range

-25 ℃~60℃

Humidity

0~99%(Indoor Type Design)

Waterproof

Indoor Type Design

Electromagnetic Compatibility

EN50081.part1   EN50082.part1

Power System Disturbance

EN61000-3-2  EN60950-1

Network test

DIN VDE 1026


Packing and weight:

N.W

0.77kg(200-300W)

1.3kg(400—600W)

2.0kg(800—1000W)

G.W

1.15kg(200—300W)

1.8kg(400—600W)

2.5kg(800—1000W)

Size (L x W x H)

18.7 x 12.6 x 5.1 cm

21 x 16.5 x 5.3cm

31 x 16.5 x 5.5cm

Packing (L x W x H)

          cm

Inner box: 27x19.3 x 9.5

Outer box: 49x28.5x 41.5

Inner box: 30x20.3x11.3

Outer box: 42x31.5x36.5

Inner box: 39 x 20.3 x 11.3

Outer box: 42x31.5x36.5

AC Power Cord

1.8 m

1Please read the below notes carefully before installation. 

 A) Make sure the open voltage and operation voltage is in the range of 10.5-28V, and we recommend the 18V rated voltage solar panel or 24V battery.

 B) Make sure the inverter’s AC voltage and frequency is the same with power grid voltage and frequency.

 C) Installation inverter in the low humidity and well-ventilated place to avoid the inverter damp and overheating, And clear the inflammable and explosive materials around.

 D) Recommended to use 4AWG DC input cable that can handle more than 50A current.

 E) DC input cable no more than 8M, because long DC cable will reduce the voltage from solar panel     to inverter, then make some loss.

 F) There must be a circuit breaker between solar power generation and power grid(show like the  “ switch  A” in figure 1). And there will be no load before the circuit breaker.

 G) Before connect all the connections, you must disconnect the utility power. After make sure the all    connections are right then connect the utility power.

 H) If you need to disconnect the mains switch when the solar power generation is in operation, you

 must disconnect the control switch first(show like the “switch  A” in figure 1).

 I)  Avoid children touch or play the inverters, in order to prevent electric shock.

 J) Non-professional do not disassemble the inverter, only qualified serviceman can repair it.

2Connection DC terminal

   Connect the solar panels positive terminal to inverter’s positive terminal, and negative to negative. And you must screw up the nut to avoid the bad contact. 

3、Connection of AC terminal 

   Before connect the inverter’s AC cable to the socket, you must disconnect the utility power. Then put the AC cable which has holes terminal into the inverter’s 3 feet port and the pin terminal to the socket. Please make sure both of the terminal are connect fastness to avoid bad contact.   

4Operation

   After all connection, first open the mains switch, then open the inverter. When the inverter’s green LED shows, it means the inverter start to work.

5Several or many inverters used in parallel.

   In order to achieve higher power, we can use this inverter in stack. For example: 4 pcs of 300W grid tie inverter used in stack can achieve 1200W. And the stacking number is unlimited. 

LED Indicator                                           

ARed LED 

   1、Low-voltage protection (input DC voltage is less than 10.5VDC).

   2、Over-voltage protection (Input DC voltage is greater than 28.5VDC).

   3、Over-temperature protection (when the chassis temperature is above 75℃ the temperature dropped about 2-10 minutes to restart automatically after cooling).

   4、Fault Protection (when 110VAC or 220VAC power outage or shutdown).

   5、Islanding protection: When the electric supply stop, the inverter automatically shut down output.

BGreen LED 

   1、Green LED flashing: The inverter is adjusting power output. MPPT is in working condition.

   2、Green LED long in time: The inverter is in working condition with the maximum output power.

Accessories for product                                             

One standard AC wire

One user manual 

  • Related Products